MALLORY IGNITION www.mallory-ignition.com
COMP PUMP
®
SERIES 60FI
ELECTRIC FUEL PUMP
PART NO. 4060FI
NOTE: DO NOT RUN THIS PUMP WITHOUT FUEL (EXCEPT FOR BRIEF PERIODS WHILE PRIMING).
INSTALLATION INSTRUCTIONS
FORM 1061 (REV. G) 01/12
PARTS INCLUDED IN THIS KIT
4 Nuts, 5/16” – 24
4 Washers, Steel 5/16” Flat
4 Bolts, Steel 5/16”
1 Ring Terminal
1 Fuse, 7.5 AMP
1 Fuse Holder
GENERAL INFORMATION
The COMP PUMP
®
60FI Series Electric Fuel Pump
is a high pressure fuel pump designed for fuel
injection applications. This fuel pump must be used with
return style (bypass) fuel pressure regulators.
Using this fuel pump with any other kind of fuel
pressure regulator (or no regulator) will result in
severe fuel pump damage, and will void the product
warranty.
At the bottom of the fuel pump is an air bleed system
designed to help in priming the fuel pump. The air
bleed line is plumbed to the fuel return line. If the fuel
pressures you are running are 10 PSI or less, put a
1/8 NPT plug in the air bleed port.
Be sure to install a suitable fuel filter (maximum 100
micron filtration) between the fuel tank and the fuel
pump. This prevents debris from becoming wedged
in the fuel pump’s Gerotor and locking it.
An additional fuel filter (maximum 10 micron, such
as the Mallory 160 Series COMP FILTER
®
Part
No. 3160) must be placed between the fuel pump
and the injectors. This prevents debris from clogging
the injectors.
SPECIFICATIONS
Maximum recommended operating pressure:
55 psi continuous, 65 psi intermittent
Minimum oil pressure switch current rating: 7.5 amps
Fuel pump over current protection: 7.5 amp fuse
Fuel application: Gasoline
This product is covered under one or more of the
following U.S. patents: 5,007,806; 4,998,557;
5,111,793; 5,123,436; 5,186,147.
SERVICE PARTS
Brush Kit 3146A
Seal and Repair Kit 3165
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - ELECTRIC FUEL PUMP

1MALLORY IGNITION www.mallory-ignition.comCOMP PUMP® SERIES 60FIELECTRIC FUEL PUMPPART NO. 4060FINOTE: DO NOT RUN THIS PUMP WITHOUT FUEL (EXCEPT FOR

Seite 2 - MAINTENANCE—PUMP DISASSEMBLY

2www.mallory-ignition.com MALLORY IGNITIONMOUNTING PROCEDUREStep 1Mount the pump as close as possible to the fuel tank (at or below the level of the

Seite 3 - FUSE (7.5 AMP)

3MALLORY IGNITION www.mallory-ignition.comAIR BLEEDFUELFILTERFUELPUMPREGULATORFUELFILTERFUEL RETURNFUELTANKCOMP FILTER®PA RT NO.3140 OR 3500COMP FILT

Seite 4

4 www.mallory-ignition.comMALLORY IS A TRADEMARK OF PRESTOLITE PERFORMANCE10601 MEMPHIS AVE. #12, CLEVELAND, OH 44144216.688.8300FAX 216.688.8306FORM