COMP PUMP
®
SERIES 70
ELECTRIC FUEL PUMP
PART NO. 4070LP
INSTALLATION INSTRUCTIONS
FORM #1394 (REV. D) 01/12
NOTE: DO NOT RUN THIS PUMP WITHOUT FUEL
(EXCEPT FOR BRIEF PERIODS WHILE PRIMING).
SPECIFICATIONS
Operating pressure: 3–4 PSI
Fuel pump inlet/outlet thread sizes: 3/8” NPT
Oil pressure switch rating: 5 AMP
Fuel pump over current protection: 5 AMP fuse
Fuel applications: Gasoline
Service Parts PN 3146A Brush Kit
PN 3164 Seal/Repair Kit, Gasoline
PARTS INCLUdEd IN ThIS kIT
1 Electric Fuel Pump
2 Nuts, 5/16” – 24
2 Bolts, Steel 5/16”
2 Washers, Steel 5/16” Flat
1 Splice Connector
1 Ring Terminal
GENERAL INFORMATION
The COMP PUMP
®
70 Series Electric Fuel Pump is a low volume fuel
pump designed for automotive applications. The operating fuel pres-
sure is factory set at 3-4 PSI. A fuel pressure regulator is not used.
We recommend a 5/16” or larger fuel line with this fuel system.
When installing the fuel pump ttings, use a thread sealant compound
(you can nd this at a hardware store) on the tting threads. Do not
use thread sealing tape. Thread sealing tape can get into the Gerotor
and lock the pump. Also, do not overtighten the ttings. This could
damage the fuel chamber.
The fuel pump output pressure can be slightly adjusted on the vehicle
using a fuel pressure gauge. To change the fuel pump output pres-
sure, release the jam nut and remove bypass plug. Clean the bypass
plug. Apply thread sealant compound to the bypass plug threads.
Install bypass plug. Turning the bypass plug clockwise increases fuel
pressure. Tighten the jam nut.
Be sure to install a suitable fuel lter (minimum 40 micron ltration)
between the fuel tank and the fuel pump. The Mallory COMP FILTER
®
Series Part Nos. 3140 is recommended. This prevents debris from
becoming wedged in the fuel pump’s Gerotor and locking it.
MOUNTING PROCEdURE
Step 1
Mount the pump as close as possible to the fuel tank (at or below the
level of the fuel tank pickup) in a well ventilated area with minimal
exposure to road debris. Avoid exposing the pump and fuel lines to
moving parts and hot surfaces, such as the exhaust system. NOTE:
Increasing distance between the pump and tank will decrease
pump efciency.
Step 2
Using the pump mounting bracket as a template, locate mounting
holes on a solid member, such as the vehicle chassis. Drill holes for
5/16” bolts. See Figure 1. NOTE: To ensure against a potential re
hazard from pump ooding, mount the pump in a vertical posi-
tion with the motor on top.
Step 3
Connect fuel lines as shown in Figure 2. If your fuel system requires
a fuel pressure regulator, proceed to the instructions with the fuel
pressure regulator.
1
This product is covered under one or more of the following U.S. Patents:
5,007,806; 4,998,557; 5,111,793; 5,123,436; 5,186,147.
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - ELECTRIC FUEL PUMP

COMP PUMP® SERIES 70ELECTRIC FUEL PUMPPART NO. 4070LPINSTALLATION INSTRUCTIONSFORM #1394 (REV. D) 01/12NOTE: DO NOT RUN THIS PUMP WITHOUT FUEL(EXCEPT

Seite 2 - MAINTENANCE–PUMP dISASSEMBLY

WIRING PROCEdUREWiring the pump to an oil pressure switch will provide power only when the ignition switch is on and the engine is running. This will

Seite 3 - FIGURE 2

3FIGURE 4IGNITION SWITCHTO ACCESSORIESTO COIL (+)FROMVEHICLEBATTERYFUSE (5 AMP)BLACKREDFUELPUMPGROUNDIGNITION SWITCHTO ACCESSORIESTO COIL (+)FROMVEHIC

Seite 4 - WIDE GAP FACES TO THE REAR

MALLORY IS A TRADEMARK OF PRESTOLITE PERFORMANCECLEVELAND, OHIO216.688.8300 FAX 216.688.8306www.malloryperformance.comFORM #1394REV. D (01/12)MADE IN